Robinair Customer Service/Tech Support can be contacted at
1-800-533-6127 or mail at
orders@service-solutions.com. Robinair is a major manufacturer as well as supplier of vehicle electronic diagnostic equipment and a wide range of servicing tools and equipment. Robinair became a Bosch brand and was integrated into the Automotive Service Solutions Business Unit
Robinair Contact Support
Robinair Automotive | Robinair HVAC/R |
---|
Customer Service800-533-6127 orders@service-solutions.com | Customer Service800-327-5060 atporders@service-solutions.com |
Technical Support 800-533-6127 techsupport@robinair.com | Technical Support800-327-5060 atptechsupport@service-solutions.com |
International Customer Service 507-455-7223 intl.inquiries@service-solutions.com | International Customer Service507-455-7223 intl.inquiries@service-solutions.com |
Service Repair800-822-5561 techsupport@robinair.com | Repairs800-344-4013 eservice.AA-AS@us.bosch.com |
Mailing Address Bosch Automotive Service Solutions 28635 Mound Road Warren, MI 48092 USA | Mailing Address Bosch Automotive Service Solutions 28635 Mound Road Warren, MI 48092 USA |
Robinair 34788ni Manual/Filter Change/Instructions/Filter Location
Robinair 34788ni
manual has the content about Initial Setup, Operating Instructions, Maintenance
, Replacement Parts and Glossary, Troubleshooting Messages, Storage and Transportation of Equipment.
Robinair 34788ni High Tank Pressure
In case Robinair 34788ni display shows "High Tank Pressure". The cause for this is Robinair 34788ni is locked out due to pressure in ISV is too high because of excessively high tank temperature. The solution is to allow Robinair 34788 to cool before performing additional A/C service. If the problem continues, contact a Robinair authorized service center as mentioned above.
Robinair 34788ni Service Password
Typically the password is 1234, if in case this does not work then try removing power from the thermostat for about 30 min to reset it to factory defaults. Then try again 1234 still facing issue call at
1-800-533-6127Robinair 34788ni Parts/Diagrams/Sale/Replacement Hoses
Robinair 34788ni Parts with diagrams are available at Robinair official website
www.robinair.com. Still facing any issue regarding parts availability, contact above mentioned contact numbers.
Robinair 34788ni Troubleshooting/Issues
Display | Cause | Solution |
---|
Calibration Check Failed | Internal scale is out of calibration | Select refresh retry calibration. If calibration continues to fail, contact a Robinair service center for repair 800-344-4013 |
Database Not Available | Machine is not with database installed | Contact a Robinair service center |
Excess Tank Weight | Overfill safety circuit. The machine is locked because of too much refrigerant in ISV | Contact a Robinair service center |
Invalid Code | Activation code is not correct | Verify activation code exactly as received. Capitalization is required |
Note: Troubleshooting Other than above mentioned problem call at
800-533-6127Robinair 34788ni Cover
Dust cover for Robinair 34788ni is available at officical website
https://www.robinair.com/ or any other e-commerce website
Robinair 34788ni Tank Fill
Use the Setup Menu of the Robinair 34788ni to transfer refrigerant from a source tank to the ISV. The tank fill value can be adjusted up or down. Transfers refrigerant from a source tank to the
Internal storage vessel (ISV) in the machine. The maximum capacity of the ISV is 10 kg which is about (22 lb). Use arrow keys to move the cursor and use the keypad to enter a value
Robinair 34788ni Activation Code
On the personal computer type the Personal Product Code of the Robinair 34788ni into the Product Activation key
Box on the official website to receive an activation code for Robinair 34788 Ni. On the Robinair 34788ni, type the activation code received into the correct field.
Note: Type the Activation code exactly as received and record the code on a piece of paper and
File it in a secure place.
Robinair 34788ni Oil Injection
Use the Robinair syringe-type injector to add lubricant oil (PAG or POE type) to the Low Side of a fully pressurized A/C system. Fill the barrel with the amount of oil needed, connect the injector, and press down the plunger.
Robinair 34788ni Vacuum Pump Oil Change
- Select "PUMP MAINTENANCE from the SETUP MENU". The display shows how long the last oil change is changed
- Choose to change vacuum pump oil. If the Robinair 34788ni displays
- Open the oil fill cap to make sure that there is no pressure in the Robinair and remove the cap
- Drain out the old oil from fitting cap. Replace the cap and close tightly. Select to continue
- Atlast slowly add vacuum pump oil through the oil fill port until the oil reaches to the center of the sight glass
Robinair 34788ni Tank Full Remove Refrigerant
If the Robinair 34788ni displays Tank Full Remove Refrigerant this means ISV is too full to recover any additional refrigerant. The solution to this is to start a charge process to remove refrigerant from ISV
before going for any further recovery attempts
Robinair 34788ni Refrigerant Identifier
Robinair 34788N recover, recycle, evacuate, leak-test and recharge R-134a. The Robinair 34788N new design has a larger graphical display, automatic features that includes leak testing, automatic refrigerant refill. 34788 also has the ability to add a printer, USB data sharing, refrigerant identifier.
Robinair 34788ni Internal/Recovery Tank Full
In such situation with power OFF carefully open the front panel cover and remove refrigerant manually from the ISV tank. Open Liquid hose from the tank press tank valve as required
Robinair 34788ni Warranty
All Robinair products including Robinair 34788ni are warranted from defects in material or in workmanship under normal use and service for a one year after the sale call at
1-800-533-6127 for warranty related queries
Robinair 34788ni Stuck on Low Side Clear/Not Recovering
Open the vacuum pump oil filling cap fir releasing the extra pressure from. Replace new relay board and follow screen message do not skip any option. Monitor the pressure transducer is working properly
Robinair 34788ni Filter Kit
Robinair 34788ni Filter Kit contains one quick filter-drier to be used on both R-134a and R-12 stations and one 16 ounce bottle of Premium Vacuum Pump Oil for further information visit official website
https://www.robinair.com/Robinair 34788ni How to Use
The Robinair 34788ni is easy to use and has superior accuracy. Robinair 34788ni recovers, recycles, leak tests, and recharges R-134a quickly as well as accurately
Robinair 34788ni Calibration
Calibration check function is used to make sure the Robinair 34788ni internal scale is calibrated. During check use only the calibration weight that is comes with the machine.
Robinair 34788ni Oil Drain Bottle
Robinair 34788ni Oil Drain Bottle is available at official website
https://www.robinair.com/ and comes with replacement instructions as well.
Robinair 34788ni Printer
Robinair Printer can be installed on most of the Robinair A/C Recover, Recycle as well as on Recharge machines, including 34288NI, 34288NI-230, 34788NI, 34788NI-H, etc.
Robinair 34788ni Filter Drier Replacement
Robinair Replacement Filter Drier is specially made for maximum acid as well as for moisture removal. Best practice is to replace filters after 60kgs of refrigerant has been recovered and is available at Robinair official website
Robinair Model 34788ni
Robinair 34788NI machines recover, recycle, evacuate, leak-test. The new design has a larger graphical display, automatic features like automatic refrigerant refill, leak testing, and oil drain/inject. 34788 also has the ability to add a printer.
| |
---|
Robinair 34788 no Power | Replace relay board and follow instructions the on screen message |
Robinair 34788ni Filter Serial Number | Filter Serial Number appears on the filter-drier |
Robinair 34788ni Vacuum Pump Not Working | Call at 1-800-533-6127 |
Robinair 34788ni Software Update | Robinair 34788ni has a USB port for Software Update |
Robinair 34788ni Circuit Board | Circuit Board allows Robinair 34788ni to be upgraded via a system card or implements changes or enhance the operation of the 34788ni |
Robinair 34788ni Reset | Reset the relay board by pressing F2 |